Small Scale Non-Invasive Imaging Using Magnetic Induction Tomography - Hardware Design

Authors

  • Ruzairi Abdul Rahim Universiti Teknologi Malaysia
  • Muhammad Saiful Badri Mansor Gleneagles Hospital Medini and Universiti Teknologi Malaysia
  • Zulkarnay Zakaria Universiti Malaysia Perlis
  • Nor Muzakkir Nor ayob KAIFA Technology Malaysia Sdn. Bhd
  • Yusri Md Yunus Universiti Teknologi Malaysia
  • Anita Ahmad Universiti Teknologi Malaysia

Keywords:

Magnetic induction tomography, excitation coil, receiving coil

Abstract

This study is conducted to preliminary image the conductivity profile through the development of small scale non-invasive Magnetic Induction Tomography (MIT) system.  It is proved that the Magnetic Induction Tomography interested in mapping the passive electrical properties of materials; conductivity (σ), permittivity (ε) and permeability (µ) in both process and medical tomography.  The system is realized by designing the functional ferrite-core coil sensors, electronic measurements circuits for excitation and receiving coil, data acquisition system for transferring the data to the PC and suitable image reconstruction algorithm for providing the conductivity distributions measurement. The important characteristic for excitation coil is the one that can maintain the stability the optimum sine wave frequency ranging from 400 kHz up to 10 MHz.  The sine waves are fed to the excitation coil through the application of high current amplifier component respectively. In the experiments, the copper phantom represent as high conductivity material were placed into the region of interest.  The initial 16 channel MIT consists of 8 excitation coil and 8 receiving coil stacked alternately.  On the receiving circuit, the major problem is the weak secondary signal perturbation sensed by the receiving coil has been improved by placing the variable amplifier on each receiver. The enhancement of conductivity profile imaging has been made by using a common Linear Back Projection (LBP) algorithm.  The measurement was done on single and dual arrangement of copper phantom aligns in random coordinate so that the sensitivity of the excitation and receiving coil sensor can be experimentally observed.  The imaging’s results show that the hardware’s and algorithm used was capable to process the data captured at the receiver.  The results obtained can be useful for further improvement and research towards magnetic induction tomography.

Downloads

Download data is not yet available.

Downloads

Published

09-08-2020

Issue

Section

Articles

How to Cite

Abdul Rahim, R., Badri Mansor, M. S. ., Zakaria, Z., Nor ayob, N. M. ., Md Yunus, Y., & Ahmad, A. (2020). Small Scale Non-Invasive Imaging Using Magnetic Induction Tomography - Hardware Design. International Journal of Integrated Engineering, 12(8), 20-30. https://publisher.uthm.edu.my/ojs/index.php/ijie/article/view/5393